Angiogram Foundation Model Screens for Severe Aortic and Mitral Valve
A multicenter research team has developed and validated a video-based deep learning foundation model that automatically screens for severe aortic stenosis and severe mitral regurgitation directly from standard invasive coronary angiography recordings. Coronary
Illustrative imageA multicenter research team has developed and validated a video-based deep learning foundation model that automatically screens for severe aortic stenosis and severe mitral regurgitation directly from standard invasive coronary angiography recordings. Coronary heart disease remains the primary cause of mortality globally, and catheter-based coronary angiography serves as the accepted gold standard diagnostic modality for evaluating coronary artery disease. Concurrently, valvular heart conditions such as severe aortic stenosis and severe mitral regurgitation frequently co-occur with coronary artery narrowing yet frequently remain unrecognized in routine clinical encounters. Severe aortic stenosis affects more than half of individuals aged seventy years and older who present with coronary disease, while coronary disease itself represents a frequent contributor to severe mitral regurgitation. Because diagnostic resources vary and symptoms such as angina can overlap between ischemic disease and valvular pathology, early opportunistic detection during already scheduled coronary procedures could alter therapeutic pathways and clinical prognosis without introducing new invasive interventions.
To evaluate whether routine fluoroscopic cineangiograms contain recognizable structural and kinetic indicators of left-sided valvular abnormalities, the investigators established CAGFound. The underlying framework leverages video-based joint-embedding predictive architecture designed to learn spatial and temporal representations from unlabeled imaging sequences across multiple hospital centers. While standard coronary angiography is conducted primarily to delineate luminal narrowing within the coronary arterial tree, the resulting radiographic sequences inadvertently capture dynamic features of surrounding anatomy, including epicardial arterial displacement, myocardial contraction patterns, cardiac remodeling, and arrhythmias. Recognizing that conventional specialized artificial intelligence models often experience performance degradation when deployed beyond their initial training distributions, the researchers pursued a self-supervised foundation model approach. Foundation architectures derive generalized internal representations from extensive corpora of unlabeled medical visual data, permitting subsequent adaptation to distinct diagnostic classifications with heightened parameter efficiency and stability across distinct institutional environments.
The pretraining cohort for CAGFound incorporated 117,383 unlabeled coronary angiographic videos collected retrospectively from 12,435 adult patients across seven healthcare institutions in China. Participating institutions included the First Medical Center, the Fourth Medical Center, and the Sixth Medical Center of Chinese PLA General Hospital, alongside Qilu Hospital of Shandong University, Boai Hospital of Hebei Province, Qixia City People’s Hospital, and Qingyun County People’s Hospital. Across this pretraining population, the average participant age was 61.65 years with a standard deviation of 10.58 years, and 8,903 individuals, representing 71.60 percent of the cohort, were male. The protocol admitted adult patients older than eighteen years who underwent standard invasive coronary catheterization, while excluding recording sequences that lacked adequate visualization of the left coronary artery or exhibited insufficient visual quality. All participating individuals had provided informed consent under ethics committee oversight in accordance with the Declaration of Helsinki.
The technical configuration of CAGFound relied on a video joint-embedding predictive architecture consisting of an online encoder, an exponential moving average momentum encoder, and a lightweight predictive projector. The online encoder utilized a vision Transformer architecture with twelve Transformer blocks and an internal embedding dimension of 768 units. Input angiography videos were resized using cubic interpolation to 224 by 224 pixels, and sixteen frames were uniformly extracted at intervals of three frames, repeating terminal frames whenever an angiographic run contained fewer than 48 continuous frames. Unmasked spatiotemporal visual cubes measuring 2 by 16 by 16 pixels were processed by the online encoder into high-level vector representations. During self-supervised pretraining, an aggressive masking ratio of 0.9 was applied, requiring the model to predict feature representations produced by the momentum encoder for the obscured video segments. Optimization proceeded across 200 epochs using a batch size of 128 on a single 80-gigabyte NVIDIA Tesla A800 graphic processor, incorporating a twenty-epoch learning rate warm-up reaching 1 by 10 to the power of negative 3, completing total training in approximately five days.
Following self-supervised representation learning, CAGFound was adapted to downstream binary classification tasks to detect severe aortic stenosis and severe mitral regurgitation by retaining the online encoder and appending a multilayer perceptron classifier. Fine-tuning required approximately one minute per one hundred images using a batch size of sixteen across ten epochs, governed by a two-epoch linear warm-up reaching 7 by 10 to the power of negative 4 followed by an eight-epoch cosine annealing decay to 1 by 10 to the power of negative 6. Label smoothing was incorporated to regularize the predictions against overconfidence, and model stability was assessed via two cycles of five-fold cross-validation. Angiographic series captured from left cranial and right cranial projection angles were specifically leveraged because these fluoroscopic orientations correspond closely to three-chamber and two-chamber transthoracic echocardiographic perspectives, optimizing visual access to both the aortic and mitral valve structures.
Validation datasets were established from patients who had undergone both invasive coronary angiography and transthoracic echocardiography within a one-month window, using the echocardiogram completed closest to the catheterization procedure as the clinical reference standard. Diagnostic severity classifications were derived from formal echocardiographic reports structured according to American Society of Echocardiography recommendations incorporating quantitative, semiquantitative, and qualitative measures. The internal severe aortic stenosis testing cohort from the First Medical Center comprised 358 angiographic sequences, including 119 confirmed cases of severe stenosis and 239 control cases. Among severe aortic stenosis patients, the mean age was 68.42 years, 57.14 percent were male, and the mean interval between imaging modalities was 5.52 days. In the non-stenosis control cohort, the mean age was lower, female representation was 28.03 percent, hypertension prevalence was 75.73 percent, and acute coronary syndromes predominated, including 81.95 percent with unstable angina, 7.95 percent with ST-segment elevation myocardial infarction, and 2.93 percent with non-ST-segment elevation myocardial infarction.
For severe mitral regurgitation, the internal testing cohort gathered from the same institution encompassed 848 angiographic sequences representing 280 severe regurgitation cases and 568 control patients. Patients presenting with severe mitral regurgitation exhibited a significantly higher mean age of 65.34 years compared to 61.70 years in non-regurgitant controls, accompanied by a lower proportion of male individuals at 48.93 percent versus 77.11 percent. The average time span separating echocardiography and angiography among severe regurgitation cases was 5.57 days compared to 3.57 days in controls, with the majority undergoing ultrasound examination prior to catheterization. Among the control subjects, clinical presentations were heavily characterized by acute coronary syndromes, comprising 88.20 percent unstable angina, 4.05 percent non-ST-segment elevation myocardial infarction, and 1.76 percent ST-segment elevation myocardial infarction.
In internal cross-validation assessments, CAGFound demonstrated strong discriminative capacity, yielding an area under the receiver operating characteristic curve of 0.932 for severe aortic stenosis along with a mean sensitivity of 0.767, specificity of 0.921, positive predictive value of 0.856, negative predictive value of 0.878, accuracy of 0.866, F1 score of 0.803, and Cohen’s kappa coefficient of 0.702. For internal severe mitral regurgitation screening, the model achieved an area under the curve of 0.933, registering a sensitivity of 0.738, specificity of 0.938, positive predictive value of 0.863, negative predictive value of 0.879, overall accuracy of 0.871, F1 score of 0.793, and Cohen’s kappa coefficient of 0.700. These internal metrics verified that spatiotemporal representations captured during self-supervised learning preserved meaningful diagnostic signals regarding cardiac valve dysfunction.
Generalization capability was subsequently appraised on independent external validation cohorts collected between 2021 and 2025 at the Sixth Medical Center of Chinese PLA General Hospital. The external aortic stenosis evaluation set comprised 134 angiographic sequences from 45 patients with severe aortic stenosis and 89 controls, in which severe stenosis patients were older, had lower body mass indices, and displayed higher female representation. In this external cohort, CAGFound attained an area under the curve of 0.879 with a 95 percent confidence interval spanning 0.809 to 0.948, accompanied by a sensitivity of 0.800, specificity of 0.955, positive predictive value of 0.900, negative predictive value of 0.904, accuracy of 0.903, F1 score of 0.847, and Cohen’s kappa of 0.776. The external mitral regurgitation cohort contained 207 sequences from 69 patients with severe regurgitation and 138 controls, where severe cases averaged 63.87 years of age, included 49.28 percent women, and exhibited a 49.28 percent hypertension rate. In testing on this cohort, the model reached an area under the curve of 0.896 with a 95 percent confidence interval from 0.844 to 0.948, sensitivity of 0.754, specificity of 0.855, positive predictive value of 0.722, negative predictive value of 0.874, accuracy of 0.821, F1 score of 0.738, and Cohen’s kappa of 0.602.
When benchmarked against established video foundation baselines, CAGFound surpassed both VideoMAEv2 and Video Swin across diagnostic accuracy, calibration metrics, and net clinical benefit. For severe aortic stenosis, VideoMAEv2 attained an area under the curve of 0.852 with a Brier score of 0.137 and an R-squared of 0.427, while Video Swin recorded an area under the curve of 0.751 with a Brier score of 0.176 and an R-squared of 0.222, trailing CAGFound’s area under the curve of 0.879, Brier score of 0.130, and R-squared of 0.481. In severe mitral regurgitation evaluations, VideoMAEv2 demonstrated an area under the curve of 0.832 with a Brier score of 0.159 and an R-squared of 0.306, while Video Swin yielded an area under the curve of 0.830 with a Brier score of 0.162 and an R-squared of 0.306, compared to CAGFound’s area under the curve of 0.896, Brier score of 0.122, and R-squared of 0.478. Decision curve analysis established that CAGFound provided greater net clinical benefit than either comparator across decision thresholds exceeding 10 percent, retaining consistent utility across the clinically relevant threshold ranges of 15 to 80 percent for mitral regurgitation and 40 to 60 percent for aortic stenosis.
Interpretability assessments using saliency heatmaps illustrated that the model directed attention to anatomically plausible cardiac regions when formulating diagnostic probabilities. For severe aortic stenosis predictions, visual attention concentrated upon the aortic valve, the left atrium, and the broader cardiac silhouette, matching documented pathological phenomena such as left ventricular hypertrophy and valve calcification. For severe mitral regurgitation predictions, saliency mapping localized focus predominantly to the mitral valve apparatus and the left atrium, mirroring known clinical correlates including left atrial dilation and annular enlargement. Furthermore, the pretraining framework demonstrated generative capacity by reconstructing structural video frames from masked inputs. From an operational perspective, the model operates at an inference throughput of 30 samples per second, functioning as an automated background screening alert without requiring operator disruption, supplementary catheter manipulation, or additional iodinated radiocontrast administration, which holds particular relevance for the 10 to 30 percent of evaluated patients exhibiting stage 3 or worse chronic kidney disease.
The study authors identified several key methodological and clinical constraints governing the interpretation of their findings. The research was conducted retrospectively across hospital records rather than as a prospective real-world trial, meaning prospective workflow validation remains necessary before active deployment. Additionally, the downstream models were configured solely as binary classifiers for severe aortic stenosis and severe mitral regurgitation, omitting intermediate disease severities and excluding other prevalent valve pathologies such as aortic regurgitation, mitral stenosis, or tricuspid regurgitation. The investigators emphasized that the foundation model is intended to function as an automated, high-sensitivity opportunistic screening trigger to prompt formal transthoracic echocardiography rather than serving as a standalone definitive diagnostic replacement for standardized echocardiographic evaluations.
Subject of Research: Deep learning foundation model for automated opportunistic screening of severe valvular heart disease from coronary angiography videos
Article Title: Foundation model for screening severe mitral regurgitation and severe aortic stenosis from coronary angiograms
Article References: Zhang, Y., Shao, Z., Wei, Z., Liu, C., Sun, Z., Liu, L., Xin, R., Ge, Y., Wang, C., Ding, G., Gao, L., Zhang, L., Hui, H., Tian, J., & Chen, Y. (2026). Foundation model for screening severe mitral regurgitation and severe aortic stenosis from coronary angiograms. Visual Computing for Industry, Biomedicine, and Art, 9(1), Article 10. https://doi.org/10.1186/s42492-026-00221-5
Image Credits: AI Generated
DOI: 10.1186/s42492-026-00221-5
Keywords: Coronary Angiography, Aortic Stenosis, Mitral Regurgitation, Valvular Heart Disease, Foundation Model, CAGFound, Self-Supervised Learning, Deep Learning, Vision Transformer, Cardiac Imaging, Opportunistic Screening, Decision Curve Analysis, VideoMAEv2, Video Swin, Transthoracic Echocardiography, Medical AI, Cardiovascular Disease
News Source: Scienmag.